Send Message
Home ProductsElisa Test Kit

E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision

Certification
China Biovantion Inc. certification
Customer Reviews
Very good. everything was complete. Thanks

—— Maryl Joy Prado-Philippines

Very good and easy communication. The products worked well with both positive controls and test groups. Would order again without hesitation.

—— Olof Olson,United States

I'm Online Chat Now

E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision

E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision
E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision

Large Image :  E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision

Product Details:
Place of Origin: CHINA
Brand Name: BIOVANTION
Certification: ISO 13485
Model Number: TY0031
Payment & Shipping Terms:
Minimum Order Quantity: 1000 Box
Price: discussible
Packaging Details: carton/box
Delivery Time: 2-7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100000 Box/carton

E2 ELISA Test Kit In Vitro Detection Medical Detection High Precision

Description
Delivery: Within 48 Hours Packaging Specifications: 8 X 12 Strips, 96 Wells
Country Of Origin: China,BeiJing Detection Limit: 18 Months
Storage: 2-8℃ Specimen: Whole Blood
Assification: Class1 Product Type: Elisa Test Kit
High Light:

E2 ELISA Test Kit

,

E2 Elisa diagnostic kit

,

High Precision ELISA Test Kit

                                                    E2 ELISA Test Kit

INTENDED USE

Detection Kit for Estradial (E2)(ELISA).It is used in quantitative tests for Estradial in human serum.

Product list

Product detailsDescription
DeliveryWithin 48 hours
Packaging Specifications8 x 12 strips, 96 wells
Country Of OriginChina
Manufacturer18 months
Preservation method2℃-8℃
SpecimenWhole blood
Assificationclass1
TypeElisa Test Kit

 

PRINCIPLE

E2 kit is based on competitive method. Coat micro well plates with E2 antibody. Add E2 calibrator (or patient sample) and HRP-E2 to form E2-antibody—HRP-E2 complex. The binding amount of HRP-E2 is reversely proportional to E2 content in serum. Remove the unbound E2-HRP. Add substrate and detect absorbent value. Calculate E2 content of patient serum through computer or plotting fitting concentration-absorbent value curve.
 

MAIN COMPONENTS

Coated Microplate: 1 plate (8×12 wells), Ready to use. Coated with anti-T4 antibody and sealed in an aluminum bag. Remove the strips in the resealable bag with a desiccant to protect from moisture after opened. Store at 2~8℃ until expiration date.

  • Biotin-T4: 1 vial of 6ml, Ready to use. Store at 2~8℃ until expiration date.
  • Avidin-HRP Conjugate: 1 vial of 6ml, Ready to use. Store at 2~8℃ until expiration date.
  • Calibrator: 6 vials of 1ml, Ready to use. Labeled with S0 to S5 and the concentration of T4 is 0,20,40, 80,160,320 ng/ml. Store at 2~8℃ until expiration date.
  • Control: 2 vials of 1ml, Ready to use. Labeled with high value and low value. Store at 2~8℃ until expiration date. The concentration of low value is 44.3~82.3 ng/ml. The concentration of high value is 112~208 ng/ml.
  • Chromogen A: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Chromogen B: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Stop Solution: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Wash buffer: 1 vial of 15ml, Concentrate 20-fold, diluting with deionized water before the assay. Store at 2~8℃ until expiration date.
  • Plate sealer: 2 pieces.
  • Plastic resealable bag: 1 set.
  • Instruction manual: 1 copy.

RELATED TIPS

  • This kit is designated for In-Vitro Diagnostic Use Only.
  • Wash procedure. Incomplete washing will adversely affect the test results. Wash each well 3 times with about 0.3ml diluted washing solution. If no automatic washer is available, washing can be performed manually as follows: Invert the plate vigorously to get all water out and block the rim of well on absorbent paper for a few seconds. Filling each well with diluted washing solution and remain 10 seconds. Repeat these steps 3 times. Blot dry the plate by inverting the plate onto absorbent tissue, and striking a hard surface several times.
  • Drip procedure. Mix the bottle gently before use. Violent surge may cause too much foam. Invert the bottle and squeeze one or two drop on absorbent tissue to make sure there is no foam. Take the bottle upright the well and make sure the drop does not touch the rim of wells.
  • Storage. The whole kit should be stored at 2~8℃ for one year. Microplate should be taken to room temperature before opened. This is very important because absorbed atmospheric moisture by cold plates significantly reduces their shelf life. After removing the required number of strips, the plate should be put in the plastic resealable bag with desiccants to minimize exposure to damp air.
  • Read Procedure. Determine the absorbance (OD) of each well at 450nm with a microtiter plate reader. Using the blank well to correct the zero point of reader if single wavelength reader is used. If double wavelength readers with 450nm and 630nm are used, there is no need to correct the zero point.
  • Control serum is prepared with human serum, which is tested negative of HBV, HCV and HIV. But it should still be considered as capable of transmitting viral diseases.

PREPARATIONS

1.  Allow all specimens and reagents to reach room temperature (~25°C) and mix thoroughly by gentle inversion before use.
2.Prepare Wash Buffer by diluting Wash Concentrate 20-fold with deionized water. The diluted wash solution is stable in room temperature for at least one week.

ATTENTIONS

1. Do not exchange reagents from different lots or use reagents from other commercially available kits. The components of the kit are precisely matched for optimal performance of the tests.
2. Specimens with Hyperlipidemia and icterus show no effects on the detection results. But specimen with severe hemolysis will affect the color of the result, other test methods are suggested to use.
3. Allow the reagents and specimens to reach room temperature before use. Shake reagent gently before use.
4. Concentrated washing liquid will produce crystal at room temperature, should be diluted completely before use.
5. Never reuse microplate sealing membrane.
6. Samples containing anti-sperm antibody, anti-endometrial antibody will not affect the results.
7. Each component of the kit was inactivated, however, it should be regarded as potentially infectious.
 

PRECAUTION FOR USERS

1. Handling should preclude any pipetting by mouth. Use only pipettes with disposable tips for each specimen.
2.Do not mix materials from different master lots. Do not use kit components beyond the expiration date.
3.All materials should be brought to room temperature before use.