Send Message
Home ProductsElisa Test Kit

Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use

Certification
China Biovantion Inc. certification
Customer Reviews
Very good. everything was complete. Thanks

—— Maryl Joy Prado-Philippines

Very good and easy communication. The products worked well with both positive controls and test groups. Would order again without hesitation.

—— Olof Olson,United States

I'm Online Chat Now

Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use

Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use
Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use

Large Image :  Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use

Product Details:
Place of Origin: CHINA
Brand Name: BIOVANTION
Certification: ISO 13485
Model Number: TY0031
Payment & Shipping Terms:
Minimum Order Quantity: 1000 Box
Price: discussible
Packaging Details: carton/box
Delivery Time: 2-7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100000 Box/carton

Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use

Description
Delivery: Within 48 Hours Packaging Specifications: 8 X 12 Strips, 96 Wells
Country Of Origin: China,BeiJing Detection Limit: 18 Months
Storage: 2-8℃ Specimen: Whole Blood
Assification: Class1 Product Type: Elisa Test Kit
High Light:

Thyroxine Elisa detection kit

,

T4 Elisa detection kit

,

High Accurate Elisa immunoassay kit

                         Thyroxine(T4)ELISA Test Kit (Serum)

INTENDED USE

   Detection Kit for thyroxine(T4)(Enzyme-Linked ImmunoSorbent Assay , ELISA). It is used in quantitative tests for thyroxine(T4) in human serum.

SUMMARY AND CLINICAL SIGNIFICANCE

   

The thyroid gland essential for the development of most tissues and for the adjustment of their metabolism. These processes are under the control of thyroid hormones, T4 and T3.

Under stimulation by pituitary thyrotropin (TSH), the thyroid gland essentially secretes T4 with minute amounts of T3. Tissue receptors to thyroid hormones are T3 receptors; T3 represents thus the active entity of thyroid secretions. Nevertheless, T4 determination is of great clinical significance, since serum T4 level is correlated to the secretory rate of the gland. More over T4 represents a precursor hormone available for peripheral deiodination into T3. In assuming serum T4 level, one has to take into consideration both the thyroid secretory rate and deiodination process

Product details Description
Delivery Within 48 hours
Packaging Specifications 8 x 12 strips, 96 wells
Country Of Origin China
Manufacturer 18 months
Preservation method 2℃-8℃
Specimen Whole blood
Assification class1
Type Elisa Test Kit

Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use 0Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use 1Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use 2Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use 3Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use 4

PRINCIPLE

T4 kit is based on competitive method. Coat micro well plates with anti-T4 to form solid-phase antibody. The T4 of sample and biotin-T4 compet with anti-T4 on solid-phase. Equilibrium, avidin-HRP added, solid phase antibody-biotinylated T4-avidin-HRP complex was formed. Add substrate and detect absorbent value. Calculate T4 content of patient serum through computer or plotting fitting concentration-absorbent value curve.

 

MAIN COMPONENTS

Coated Microplate: 1 plate (8×12 wells), Ready to use. Coated with anti-T4 antibody and sealed in an aluminum bag. Remove the strips in the resealable bag with a desiccant to protect from moisture after opened. Store at 2~8℃ until expiration date.

  • Biotin-T4: 1 vial of 6ml, Ready to use. Store at 2~8℃ until expiration date.
  • Avidin-HRP Conjugate: 1 vial of 6ml, Ready to use. Store at 2~8℃ until expiration date.
  • Calibrator: 6 vials of 1ml, Ready to use. Labeled with S0 to S5 and the concentration of T4 is 0,20,40, 80,160,320 ng/ml. Store at 2~8℃ until expiration date.
  • Control: 2 vials of 1ml, Ready to use. Labeled with high value and low value. Store at 2~8℃ until expiration date. The concentration of low value is 44.3~82.3 ng/ml. The concentration of high value is 112~208 ng/ml.
  • Chromogen A: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Chromogen B: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Stop Solution: 1 vial of 7ml, Ready to use. Store at 2~8℃ until expiration date.
  • Wash buffer: 1 vial of 15ml, Concentrate 20-fold, diluting with deionized water before the assay. Store at 2~8℃ until expiration date.
  • Plate sealer: 2 pieces.
  • Plastic resealable bag: 1 set.
  • Instruction manual: 1 copy.

RELATED TIPS

  • This kit is designated for In-Vitro Diagnostic Use Only.
  • Wash procedure. Incomplete washing will adversely affect the test results. Wash each well 3 times with about 0.3ml wash buffer. If no automatic washer is available, washing can be performed manually as follows: Invert the plate vigorously to get all wash buffer out and block the rim of well on absorbent paper for a few seconds. Filling each well with water and remain 10 seconds. Repeat these steps 3 times. Blot dry the plate by inverting the plate onto absorbent tissue, and striking a hard surface several times.
  • Drip procedure. Mix the bottle gently before use. Violent surge may cause too much foam. Invert the bottle and squeeze one or two drop on absorbent tissue to make sure there is no foam. Take the bottle upright the well and make sure the drop does not touch the rim of wells.
  • Read procedure. Using the blank well to correct the zero point of reader if single wavelength reader is used. If double wavelength readers with 450nm and 630nm are used, there is no need to correct the zero point.

Storage. The whole kit should be stored at 2~8℃ for one year. Microplate should be

 

PREPARATIONS

1.  Allow all specimens and reagents to reach room temperature (~25°C) and mix thoroughly by gentle inversion before use.

2.Prepare Wash Buffer by diluting Wash Concentrate 20-fold with deionized water. The diluted wash solution is stable in room temperature for at least one week.

ATTENTIONS

1. Do not exchange reagents from different lots or use reagents from other commercially available kits. The components of the kit are precisely matched for optimal performance of the tests.

2. Specimens with Hyperlipidemia and icterus show no effects on the detection results. But specimen with severe hemolysis will affect the color of the result, other test methods are suggested to use.

3. Allow the reagents and specimens to reach room temperature before use. Shake reagent gently before use.

4. Concentrated washing liquid will produce crystal at room temperature, should be diluted completely before use.

5. Never reuse microplate sealing membrane.

6. Samples containing anti-sperm antibody, anti-endometrial antibody will not affect the results.

7. Each component of the kit was inactivated, however, it should be regarded as potentially infectious.

 

PRECAUTION FOR USERS

1. Handling should preclude any pipetting by mouth. Use only pipettes with disposable tips for each specimen.

2.Do not mix materials from different master lots. Do not use kit components beyond the expiration date.

3.All materials should be brought to room temperature before use.Thyroxine T4 Elisa Detection Kit High Accurate detection Hospital and laboratory use 5