Send Message
Home ProductsElisa Test Kit

Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA

Certification
China Biovantion Inc. certification
Customer Reviews
Very good. everything was complete. Thanks

—— Maryl Joy Prado-Philippines

Very good and easy communication. The products worked well with both positive controls and test groups. Would order again without hesitation.

—— Olof Olson,United States

I'm Online Chat Now

Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA

Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA
Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA

Large Image :  Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA

Product Details:
Place of Origin: CHINA
Brand Name: BIOVANTION
Certification: ISO 13485
Model Number: TY0031
Payment & Shipping Terms:
Minimum Order Quantity: 1000 Box
Price: discussible
Packaging Details: carton/box
Delivery Time: 2-7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100000 Box/carton

Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA

Description
Delivery: Within 48 Hours Packaging Specifications: 8 X 12 Strips, 96 Wells
Country Of Origin: China,BeiJing Detection Limit: 18 Months
Storage: 2-8℃ Specimen: Whole Blood
Assification: Class1 Product Type: Elisa Test Kit
Product Name: CA12-5 Elisa Test Kit Package: Carton/Box
High Light:

Laboratory Human Anti-Mullerian hormone amh elisa

,

Hospital Human Anti-Mullerian hormone amh elisa

,

High Precision Human AMH ELISA

    1 Human Anti-Mullerian Hormone(AMH)ELISA

INTENDED USE

  This kit is used to assay the Anti-Mullerian Hormone(AMH)in the sample of Human’s serum, blood plasma, and other related tissue Liquid.

Test principle

  The kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) to assay the level of Human Anti-Mullerian Hormone(AMH)in samples. Add Anti-Mullerian Hormone(AMH) to monoclonal antibody Enzyme well which is pre-coated with Human Anti-Mullerian Hormone(AMH)monoclonal antibody, incubation; then, add Anti-Mullerian Hormone(AMH)antibodies labeled with biotin, and combined with Streptavidin-HRP to form immune complex; then carry out incubation and washing again to remove the uncombined enzyme. Then add Chromogen Solution A, B, the color of the liquid changes into the blue, And at the effect of acid, the color finally becomes yellow. The chroma of color and the concenthumanion of the Human Substance Anti-Mullerian Hormone(AMH)of sample were positively correlated.

Product details Description
Delivery Within 48 hours
Packaging Specifications 8 x 12 strips, 96 wells
Country Of Origin China
Manufacturer 18 months
Preservation method 2℃-8℃
Specimen Whole blood
Assification class1
Type Elisa Test Kit

 Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA 0

 

Materials required but not supplied

1. 37 ℃ incubator

2. Standard Enzyme reader

3. Precision pipettes and Disposable pipette tips

4. Distilled water

5. Disposable tubes for sample dilution 

6. Absorbent paper

 

Important Notes

1. Beening taken out from the 2-8℃ environment, the kit should be balanced 30 minutes in the ambient temperature then use. If the Coated plates of Enzyme haven’t been used up after opened, the remaining plates should be stored in Sealed bag.

2. For each step, add Sample with sample injector which should be calibrated frequently, in order to avoid unnecessary experimental tolerance.

3. he operation shall be carried out accordance to the instructions strictly. And test results must be based on the readings of the Enzyme reader.

4. In order to avoid cross-contamination, it is forbidden to re-use the suction head and seal plate membrane in your hands.

5. All samples, washing buffer and each kind of reject should according to infective material process.

6. The idle agents shall be put up or covered. Do not use reagent with different batches. And use them before expired date.

7. The substrate B is light-sensitive. Prolonged exposure to light is forbidden.

Washing method

Manually washing method: shake away the remain liquid in the enzyme plates; place some bibulous papers on the test-bed, and flap the plates on the upside down strongly. Inject at least 0.35ml after-dilution washing solution into the well, and marinate 1~2 minutes. Repeat this process according to your requirements.

Automatic washing method: if there is automatic washing machine, it should only be used in the test when you are quite familiar with its function and performance.

Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA 1Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA 2Laboratory Or Hospital High Precision Human Anti-Mullerian Hormone AMH ELISA 3

 

 

Contact Details
Biovantion Inc.

Contact Person: Mr. Steven

Tel: +8618600464506

Send your inquiry directly to us (0 / 3000)