Send Message
Home ProductsColloidal Gold Rapid Test

Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay

Certification
China Biovantion Inc. certification
Customer Reviews
Very good. everything was complete. Thanks

—— Maryl Joy Prado-Philippines

Very good and easy communication. The products worked well with both positive controls and test groups. Would order again without hesitation.

—— Olof Olson,United States

I'm Online Chat Now

Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay

Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay
Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay

Large Image :  Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay

Product Details:
Place of Origin: CHINA
Brand Name: BIOVANTION
Certification: ISO 13485
Model Number: TY0031
Payment & Shipping Terms:
Minimum Order Quantity: 1000 Box
Price: discussible
Packaging Details: carton/box
Delivery Time: 2-7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100000 Box/carton

Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay

Description
Delivery: Within 48 Hours Packaging Specifications: 20 Test / Kit
Country Of Origin: China,BeiJing Detection Limit: 24 Months
Storage: 2-30℃ Specimen: Whole Blood
Assification: Class1 Product Type: Rapid Test
Product Name: Group A Rotavirus Antigen Rapid Test Kit Package: Carton/Box
Highlight:

In Vitro Immunoassay Rapid Test Kit

,

Rotavirus Antigen Rapid Test Kit

                      Group A Rotavirus Antigen Rapid Test Kit

 
INTENDED USE

Group A Rotavirus Antigen Rapid Test Kit is an in vitro immunoassay for the qualitative determination of the detection of Group A Rotavirus in human faecal specimens in one step. It is for diagnosis of early infection and epidemic survey. The kit is intended only for an initial screening test and reactive samples should be confirmed by a supplemental assay such as commercial anzyme immunoassay (ELISA) or RT-PCR

 

 

Product details Description
Delivery Within 7-14 days
Packaging Specifications 20 test/kit
Country Of Origin China
Manufacturer 24 months
Preservation method 2℃-30℃
Specimen Whole blood
Assification class1
Type  Group A Rotavirus Antigen Rapid Test Kit

 
 

MATERIALS PROVIDED

25x1 tests (strip), 20x1 tests (Cassette)

Group A Rotavirus test Cassette /strip

 

Each cassette/strip contains a test strip with Goat polyclonal anti-rotavirus antibodies on the test region of the membrane and colored mouse monoclonal anti-rotavirus antibodies-gold conjugate pad.

TEST PROCEDURE

 

1. Bring Membrane Plate and samples to room temperature (20-30°C) before use (approximately 30 minutes).

2. Remove the test cassette/strip from the sealed foil pouch and place the plate on flat desk.

3. Bring all materials and specimens to room temperature (8~30℃).

4.1 Group A Rotavirus test strip

1) Add 500μl sample diluents into the test tube.

2) Add proper specimens (S:5 mm in diameter, L: 50μl) into the tube to make the concentration of the solution up to 5%~10% and mix thoroughly.

3) Deliver 100μl (2~3drops ) of diluted stool sample to the sample pad of the test strip.

4.2 Group A Rotavirus test cassette

1) To take a portion of feces (about 100mg), insert the sterile swab into a stool sample that presents the most secretion under visual inspection.

2) Open the sample collection tube and then insert the swab into the sample collection tube containing assay diluents.

3) Swirl the swab at least 10 times until the samples has been dissolved into the assay diluents and discard the swab while squeezing the swab against the wall of tube, replace the cap.

4) Deliver 100μl (2~3drops ) of diluted stool sample to the sample well of the test card.

5. Read the result in 5~10 minutes. A strong positive sample may show result earlier.

Note: Results after 15 minutes may not be accurate.

 

Test results explain

 

Positive Two pink lines appear in both C and T position

Negative Only one pink line appear in C position

Invalid: The control line next to the test line does not become visible within 10 minutes after the addition of the sample.

 

 Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 0Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 1Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 2Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 3Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 4
Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 5Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 6Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 7Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 8Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 9Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 10
 
 
 

Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 11Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 12Group A Rotavirus Antigen Rapid Test Kit In Vitro Immunoassay 13
 
 

Contact Details
Biovantion Inc.

Contact Person: Mr. Steven

Tel: +8618600464506

Send your inquiry directly to us (0 / 3000)