Send Message
Home ProductsColloidal Gold Rapid Test

For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit

Certification
China Biovantion Inc. certification
Customer Reviews
Very good. everything was complete. Thanks

—— Maryl Joy Prado-Philippines

Very good and easy communication. The products worked well with both positive controls and test groups. Would order again without hesitation.

—— Olof Olson,United States

I'm Online Chat Now

For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit

For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit
For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit

Large Image :  For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit

Product Details:
Place of Origin: CHINA
Brand Name: BIOVANTION
Certification: ISO 13485
Model Number: TY0031
Payment & Shipping Terms:
Minimum Order Quantity: 1000 Box
Price: discussible
Packaging Details: carton/box
Delivery Time: 2-7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100000 Box/carton

For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit

Description
Delivery: Within 15-20 Miuntes Packaging Specifications: 1 Pieces
Country Of Origin: China Detection Limit: 24 Months
Storage: 2℃-30℃ Specimen: Urine
Assification: Class1 Product Type: Elisa Test Kit

                             Antibody HIV 1/2 Rapid Test Kit

INTENDED USE

The reagent is used to detect the Hepatitis C Virus Antibody in serum / plasma / whole blood qualitatively. HCV is a single-stranded positive sense RNA virus, which belongs to the family of Flaviviridae. Hepatitis C caused by HCV is an infectious disease with liver as a target organ. The incubation period of hepatitis C virus infection was 2 to 26 weeks, most of the symptoms occurrs in 5 to 12 weeks after transfusion, on an average of 7.4 weeks. There is a long window period with an average of 70 days after the hepatitis C virus infection, however, some patients’ window period can be extended to 6~9 months or even longer. Hepatitis C virus antibody can be detected in most infections with a slow appearance. Generally positive results may occur 2~6 months after the attack, while some positive results occur 12 months later.

Product details Description
Delivery Within 48 hours
Packaging Specifications 25 piece/box
Country Of Origin China
Manufacturer  24months
Preservation method 2℃-30℃
Specimen urine
Assification class1
Type  Reply Test

 

Sample Requirement

1. Serum: Use disposable syringe (vacuum blood collection tube) to extract a certain amount of venous blood, and place at room temperature for blood coagulation, take the supernatant after centrifugation of blood for detection. Plasma: Use vacuum blood collection tube with anticoagulation to extract a certain amount of venous blood, and rock repeatedly, take plasma separation for detection.Whole blood: Use the fresh whole blood specimens.

2. EDTA, sodium citrate, sodium oxalate, heparin can be used as the anticoagulants.

3. Serum and plasma specimens may be stored at 2-8℃ for 3 days prior to assay, and at -20 ℃ for 2 years. Repeat freeze and thaw for no more than 3 times. Whole blood specimens with anticoagulation may be stored at 2-8℃ for 24 hour, and should be used immediately without anticoagulation. Frozen whole blood samples should not be used. (If blood coagulation occurs, serum samples are suggested to use.)

 
Test Methods
Instructions must be read entirely before taking the test. Allow the test device controls to equilibrate to room temperature for 30 minutes (20℃-30℃) prior to testing. Do not open the inner packaging until ready, it must be used in one hour if opened (Humidity: 20%~90%, Temp: 10℃-50℃)
Strip: 1. Put the strip onto the desk with the sample adding area up. 2. Drop 1 drop (25μl) of serum/plasma/whole blood vertically onto the sample pad of strip. Add about 2 drops of (100μl) specimen buffer onto the sample pad of the strip. 3. Observe the test results immediately within 15-20 minutes, the result is invalid over 20 minutes.
Cassette: 1. Take off the outer packing, put the cassette onto the desk with the sample window up. 2. Drop 1 drop (25μl) of specimen vertically into the sample hole of cassette. Add about 2 drops of (100μl) specimen buffer into the sample hole of cassette. 3. Observe the test results immediately within 15-20 minutes, the result is invalid over 20 minutes.
 
Storage
Store as packaged in the sealed pouch at 4-30°C, avoid hot and sunshine, dry place, valid for 24 months.
DO NOT FREEZE. Some protective measures should be taken in hot summer and cold winter to avoid high temperature or freeze-thaw.
 

For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit 0For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit 1For Laboratory Or Hospital High Accuracy Human Immunodeficiency Virus Antibody HIV 1/2 Rapid Test Kit 2

 

Contact Details
Biovantion Inc.

Contact Person: Mr. Steven

Tel: +8618600464506

Send your inquiry directly to us (0 / 3000)