RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)
RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

Large Image :  RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

Product Details:
Place of Origin: China
Brand Name: BIOVANTION
Payment & Shipping Terms:
Minimum Order Quantity: 50kits

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

Description
Assay Time: 2 Hours Assay Type: Immunological Assay
Detection Limit: Low Expiration Date: 18 Months
Organism: Homo Sapiens (Human) Product Type: Research Test Kit
Reactivity: Highly Reactive Sample Type: Biological Samples
Sample Volume: 50 µL Specificity: High Specificity
Test Sample Type: Serum, Plasma Test Species: Human
Time To Results: Rapid Results
High Light:

Research Use Only Test Kit

,

Ruo Diagnostic Kit

,

Ruo Assay Kit

Research test for the quantitative determination of SAA Kit in human serum on automate chemistry analyzers 

 

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric) 0

 

SAA (Serum Amyloid A) is is an acute-phase protein. During
inflammation, infectious and non-infectious diseases, its concentration in the blood can rise sharply within a few hours, and can rise to 1000 times the initial concentration. SAA is
related to HDL, and it can It regulates the metabolism of HDL
during inflammation. A particularly important feature of SAA is
that its degradation products can be deposited in different organs
in the form of amyloid A fibrils. This is a serious complication in
chronic inflammatory diseases; Elevated serum amyloid A is also
seen in atherosclerosis, diabetic nephropathy, acute myocardial
infarction, coronary heart disease, and chronic kidney disease

 

Components

 

Contents components Concentration

 

 

R1

PBS Buffer NaCl Surfactant

Antiseptic

0.1 mol/L Titer Titer

Titer

 

 

 

R2

Latex particles coated with SAA antibody

PB Buffer NaCl Surfactant

Antiseptic

>0.5mg/L

 

0.1 mol/L Titer Titer

Titer

 

 

Calibrator

/Control

SAA

Bovine serum albumin NaCl

Surfactant

Antiseptic

See Value Sheet Titer

Titer Titer

Titer

 

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric) 1

 

【Procedure】

Reagent preparation:

 

R1: Ready for use; R2: Ready for use. Wavelength:570nm Temperature:37℃

Direction: Increase

 

  Blank Tube Calibration Tube Sample Tube
Sample 2ul
Calibrator 2ul
Deionized water 2ul
R1 200μl 200μl 200μl
Mix, incubate at 37℃ for 5 minutes.
R2 40μl 40μl 40μl

Mix, incubate at 37℃ for 5 minutes, zero setting for blank

tube, read the absorbance A calibrator and A sample

Calibration

It is recommended to use the SAA Calibrators for calibration. Dissolve the lyophilized SAA calibrator with 1ml distilled water, and dilute to 6 calibrators as follows,

Dilute 1 2 3 4 5 6
CAL (μl) 200 100 50 50 25 0

Normal

Saline (μl)

0 100 150 350 375 200
ratio 1 1/2 1/4 1/8 1/16 0

Calibration Method:Spline or other non-linear method

Quality control

It is recommended to use the SAA Quality Control level 1 and level 2 for daily quality control.

Two levels of controls should be assayed at least once a day. Values obtained should fall within a specified range.

Each laboratory should establish its own internal Quality Control scheme and procedures for corrective action if controls do not recover within the acceptable tolerances.

Calculation:

The analyzer automatically calculate the analyte concentration of each sample.